The Permanent Magnet Self-Unloading Iron Remover from Tianjin Jinci Manufacturer utilizes high-performance NdFeB permanent magnet materials, achieving a magnetic field strength of up to 15,000 Gauss. It automatically removes ferromagnetic substances weighing between 0.1-35 kg from non-magnetic materials. The internal magnetic circuit is designed using computer simulation, and a well-designed double magnetic pole structure ensures long-term, trouble-free operation in harsh environments. It is suitable for industries such as mining, metallurgy, building materials, power, and chemicals, effectively protecting equipment like crushers and grinders, preventing longitudinal tearing of conveyor belts, and improving product purity.
High Efficiency: Employs NdFeB permanent magnets with a field strength of 15,000 Gauss, capable of capturing iron particles as small as 0.1mm. The iron removal rate exceeds 99%, ensuring product transparency by precisely separating trace iron oxides .
Automatic Unloading: Equipped with an automatic unloading device controlled by a PLC system, enabling timed or real-time iron discharge without manual cleaning, significantly reducing labor intensity and enabling continuous operation .
Energy Saving & Eco-Friendly: The permanent magnet type requires no excitation power, resulting in low energy consumption. Its high-temperature resistant and fully sealed design allows stable operation even in environments up to 300°C or dusty conditions .
|
Parameter |
Specification |
|---|---|
|
Rated Voltage |
380V |
|
Rated Current |
Model-dependent |
|
Magnetic Field Strength |
15,000 Gs |
|
Adaptable Belt Width |
500-2000mm |
|
Rated Suspension Height |
150-550mm |
|
Material Thickness |
≤100-500mm |
|
Excitation Power |
0.4-18kW |
|
Protection Level |
IP54/IP67 |
Case: A Ceramic Raw Material Plant in Guangdong
This plant initially had two production lines, each producing 400 tons of finished product daily. However, the raw material had an iron content above 0.14% and a whiteness degree of only 48-52, failing quality standards. After installing four KJLSL-500G electromagnetic iron removers on each line, daily production remained at 400 tons per line, but the iron content dropped to <0.1%, and whiteness exceeded 60 degrees. Product quality improved significantly, greatly enhancing competitiveness .
Q1: The iron remover isn't working. The operation indicator is on, but the excitation ammeter shows no reading. Why?
A: This is likely due to an improperly connected power supply. Check the wiring between the iron remover and the electric control cabinet .
Q2: The iron remover isn't working, and the operation indicator is off. Why?
A: This could be caused by a blown fuse in the control cabinet. Check the reason for the blown fuse and inspect the wiring for short circuits before replacing the fuse .
Q3: The iron remover trips suddenly during operation. Why?
A: Possible reasons include poor wiring, abnormal insulation, or abnormal removal resistance inside the control cabinet. Check the internal wiring, insulation, and removal resistance, and address any abnormalities promptly .